BLZRZ - TEROMECATEC 1
- MSDS: BLZRZ
- Manufacturer: EUTECTIC CORP
- Product Name: TEROMECATEC 1
- National Stock Number: 3439-00N017976
Product Identification
Product ID:TEROMECATEC 1
MSDS Date:08/02/1990
FSC:3439
NIIN:00N017976
MSDS Number: BLZRZ
Responsible Party
FLUSHING, NY 11358-9981
US
Emergency Phone: 718-358-4000
Info Phone: 718-358-4000
Cage: EO060
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: EO060
Ingredients
3). LIMITS GIVEN FOR AL.
CAS: 1344-28-1
RTECS: BD1200000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
POLYAMIDE RESIN
IRON
CAS: 7439-89-6
RTECS: NO4565500
OSHA PEL 10 MG/M3 TDUST
TRIETHYLENETETRAMINE
CAS: 112-24-3
RTECS: YE6650000
NICKEL
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3 (INSOL)
ACGIH TLV: 1 MG/M3
CHROMIUM
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SILICON
CAS: 7440-21-3
RTECS: VW0400000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CAUSES SKIN AND EYE IRRITATION OR
BURNS, RASHES, SKIN SENSITIZATION. MAY CAUSE IRRITATION TO UPPER
RESPIRATORY TRACT IF INHALED.
Explanation of Carcinogenicity:NICKEL: IARC-GROUP 1, NTP-GROUP 2;
CHROMIUM: IARC-GROUP 1, NTP-GROUP 1.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH EYES WITH WATER FOR AT LEAST 15
MINUTES. SKIN: REMOVE CONTAMINATED CLOTHING OR SHOES AND WIPE
EXCESS FROM SKIN. FLUSH WITH PLENTY OF WATER. SEEK MEDICAL
ATTENTION. INHAL: REMOV E TO FRESH AIR (SUPPORT BREATHING
(GIVEO*2/ARTF RESP) . INGEST: CALL MD IMMEDIATELY .
Fire Fighting
Flash Point:SEE SUPP DATA
Extinguishing Media:WATER, CO*2, FOAM, DRY CHEMICAL
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:MAY PRODUCE HAZARDOUS FUMES.
Accidental Release
Spill Release Procedures:USE RECOMMENDED PROTECTIVE EQUIPMENT, ADD DRY
MATERIAL TO ABSORB SPILL. PLACE IN APPROPRIATE CONTAINER FOR
DISPOSAL. FLUSH AREA WITH DILUTE 5% ACETIC ACID.
Neutralizing Agent:REFER TO SPILL PROCEDURES .
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE WITH
ADEQUATE VENTILATION. KEEP AWAY FROM OPEN FLAME AND HIGH
TEMPERATURE. MAINTAIN EXPOSURE BELOW THE GIVEN PEL/TLV.
Other Precautions:KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
VAPORS OR AIR-SUPPLIED RESPIRATOR IF AVAILABLE.
Ventilation:LOCAL EXHAUST REQUIRED. MECHANICAL (GENERAL) RECOMMENDED.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:OTHER CLOTHING SO AS TO MINIMIZE CONTACT.
EMERGENCY EYE WASH AND DELUGE SHOWER .
Work Hygienic Practices:AVOID BODILY CONTACT AND WASH THOROUGHLY AFTER
HANDLING.
Supplemental Safety and Health
SPEC GRAV: REACTOR--2.3; MATRIX--2.6. FL PT: REACTOR--365F;
MATRIX--180F.
Chemical Properties
HCC:V4
Vapor Density:>1
Spec Gravity:SEE SUPP DATA
Solubility in Water:MODERATE
Appearance and Odor:REACTOR--BEIGE PASTE, SLIGHT AMMONIA ODOR;
MATRIX--DARK GRAY PASTE, NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
MATRIX--CAN REACT VIGOROUSLY WITH STRONG OXIDIZING AGENT OR MINERAL
ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*2, CO*1, ALDEHYDES, ACIDS AND OTHER
HYDROCARBONS
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.